上海起發(fā)實驗試劑有限公司

當(dāng)前位置:上海起發(fā)實驗試劑有限公司>>Starna>>Starna

Starna

參   考   價:面議
具體成交價以合同協(xié)議為準

產(chǎn)品型號:

品       牌:

廠商性質(zhì):代理商

所  在  地:上海市

更新時間:2016-12-24 21:10:18瀏覽次數(shù):1680

聯(lián)系我時,請告知來自 化工儀器網(wǎng)
Starna,代理,科技(原Optiglass有限公司)成立于1964年,其光學(xué)知識譜系可以追溯到上世紀早期。科技有限公司是集團的全資子公司。

 Starna,Starna代理,科技,所有的產(chǎn)品制造都是在其經(jīng)過ISO 9000認證的生產(chǎn)裝置上進行的,從產(chǎn)品的設(shè)計、開發(fā)到定制生產(chǎn)機械。*的一系列工藝,包括切割,切片,研磨,拋光,常規(guī)鉆井,超聲鉆削和融合,這些都使的生產(chǎn)實現(xiàn)了一個完整的垂直整合的過程。

The Fluorescent Materials
Sample
Number
CompoundApproximate 
Molar Conc
Excitation
Wavelength
Emission
Wavelength
1Anthracene1 x 10-5360402
 Napthalene6 x 10-5290330
2Ovalene2 x 10-7342482
3p-Terphenyl5 x 10-7295338
4Tetraphenylbutadiene3 x 10-7348422
5Compound 6101 x 10-6440475
6Rhodamine2 x 10-7562573

 

 

Care of the Reference Materials

The blocks are supplied in a velvet lined case to 
protect the fine surface finish produced at manufacture. Providing that they are handled with care (cotton gloves are recommended) and always stored in the case 
provided, they should give many years of satisfactory service. Exposure to organic solvents can cause severe fogging of the surface and must be avoided, as should any attempt to clean the block with abrasive cleaners.

In the event of the surface of a block becoming soiled, it should be immersed in dilute neutral detergent solution which may be warmed to 40°. Low power ultrasonic vibration may also be used to remove the contamination. It should then be rinsed thoroughly with deionized water and dried carefully with a soft lint-free cloth.

 

Recorded Spectra

The following spectra were recorded in the ratio 
mode, using a Perkin Elmer LS50B Luminescence Spectrometer. The spectral band width for both 
excitation and emission monochromators, was 2.5 nm. Data points were recorded at 0.5 nm intervals. These spectra are specific to this instrument and the operating conditions used. Other instruments, or different 
operating conditions will produce spectra with maxima which may vary both in terms of relative magnitude and wavelength.

The corrected Spectra were recorded using a Perkin Elmer MPF44-B and should relate to others recorded in a similar manner.

 

Starna

Starna,代理,科技(原Optiglass有限

會員登錄

X

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~

以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關(guān)企業(yè)負責(zé),化工儀器網(wǎng)對此不承擔(dān)任何保證責(zé)任。

溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

撥打電話
在線留言