| 注冊| 產(chǎn)品展廳| 收藏該商鋪

行業(yè)產(chǎn)品

當前位置:
北京恒遠安諾科技有限公司>>電子電工>>繼電器>> 專業(yè)銷售dranetz K21-120 能源儀表板

專業(yè)銷售dranetz K21-120 能源儀表板

返回列表頁
  • 專業(yè)銷售dranetz  K21-120 能源儀表板
收藏
舉報
參考價 面議
具體成交價以合同協(xié)議為準
  • 型號
  • 品牌
  • 廠商性質(zhì) 經(jīng)銷商
  • 所在地 北京市
在線詢價 收藏產(chǎn)品

更新時間:2019-06-19 09:17:08瀏覽次數(shù):982

聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!

同類優(yōu)質(zhì)產(chǎn)品

更多產(chǎn)品

產(chǎn)品簡介

dranetz K21-120 能源儀表板

詳細介紹

 歡迎前來詢價

北京恒遠安諾生化科技有限公司

www.annovatek.com

:   

: nickqian8888

:錢

www.annovatek.com

Features:

  • Aggregated Energy Expense – usage and cost for all DataNodes® or monitoring instruments for a given time period;
  • Energy Expense – energy use for a particular DataNode for a specific time period compared to rate structure;
  • Energy Usage Comparison – energy use for a specific monitoring location for various time periods against a specified reference period.
  • Operating environment - Installed in any InfoNode or Encore® Series Software.
  • Input data - Accepts energy usage and demand data from any DataNode®. User must input rate structures and peak/off-peak consumption and demand parameters.
  • Output information - On-peak energy consumption in $kWHr, $/kW, and $/kVARHr Partial-peak energy consumption in $kWHr, $/kW, and $/kVARHr Off-peak energy consumption $/kWHr, $/kW, and $/kVARHr
  • Applications - Creates reports showing total energy usage, energy usage compared against total, and energy usage for specified time intervals.
  • Algorithms - Algorithms for usage comparison with rate, time, peak, penalty, and tax.
  • Description

    Encore SeriesTM enables users to understand and manage energy consumption


    UNDERSTAND AND BETTER MANAGE ENERGY CONSUMPTION

    To succeed in today’s fiercely competitive business environment, companies must reduce both production and service costs. Since energy represents a significant portion of these costs, energy management becomes a key factor in cost reduction. The ES Series Energy Management DataNode’s® are designed to help you manage energy consumption. The ES210 and ES220 DataNode’s measure more than 60 parameters, including true RMS voltage and current, kW, kVA, KVAR, power factor, frequency. The ES230/ES230s DataNode’s add Vthd, Ithd and individual harmonics to the 15th. ES Series DataNode’s are available in the standard DIN96 or DIN144 sizes and can be used as stand alone panel meters or, by adding an available Ethernet or serial interface the ES Series can be used with web browser based Encore Series Software for remote access to real time and recorded data.


    TRACK POWER FLOW AND ENERGY COSTS

    Reducing consumption during peak times or shifting loads to off-peak times can save a typical commercial or industrial facility from ten to fifty percent annually on energy costs. By monitoring energy consumption on a continuous basis using the ES Series DataNode, energy and demand data can be gathered for an entire facility and at key consumption points including energy-intensive processes and key machinery. The ES Series DataNode is part of Encore Series Software, which automatically plots and trends this data to develop daily, weekly, monthly or yearly load profiles. Encore Series Software can also alert the user to shed loads before a new demand level is reached. The available Energy Usage Answer Module® enables Encore Series Software to aggregate energy from multiple points, compute costing information and provide other advanced energy reports. This information can be reconciled with operating data from other systems, including building automation and process control, to understand how variations in facility operations affect the load profile and electricity bill.

    Facilities armed with load profile data are better positioned to negotiate energy purchase contracts. Data from the ES Series DataNode can be used to develop a price/risk curve for evaluating options such as fixed, time-of-use, and real-time pricing plans. Without this data, a facility might incur much higher energy or peak-demand charges than necessary, or carry more than the appropriate level of risk.


    EVALUATE ENERGY REDUCTION STRATEGIES

    When and where electricity is consumed is invaluable information to have when developing energy reduction strategies, which can include lighting upgrades, HVAC replacement, installation of high efficiency motors and/or adjustable speed drives and other cost saving measures. The data provided by the ES Series DataNode arms the user with the information necessary to understand your facility, its loads and energy usage profile. This information, combined with your local utilities rate structure enables you to inligently target areas of your facility in order to provide the best return on your energy reduction budget. Not only can you reduce your overall energy usage but utility charges such as power factor penalties and time of use demand penalties can be targeted for reduction by mitigating such problems or shifting loads to less expensive times of the day.

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復(fù)您~
二維碼 意見反饋
在線留言