基睿儀器(上海)有限公司
主營(yíng)產(chǎn)品: EXTECH代理,EXTECH中國(guó)特級(jí)代理,EXTECH一級(jí)代理,EXTECH供貨平臺(tái) |
聯(lián)系電話
基睿儀器(上海)有限公司
主營(yíng)產(chǎn)品: EXTECH代理,EXTECH中國(guó)特級(jí)代理,EXTECH一級(jí)代理,EXTECH供貨平臺(tái) |
聯(lián)系電話
參考價(jià) | 面議 |
更新時(shí)間:2017-05-15 20:02:00瀏覽次數(shù):405
聯(lián)系我們時(shí)請(qǐng)說明是化工儀器網(wǎng)上看到的信息,謝謝!
日本日置HIOKI 3452-11 指針式兆歐表是目前市場(chǎng)上銷售比較好的指針式兆歐表?。▽?duì)于干擾較強(qiáng)的測(cè)試現(xiàn)場(chǎng),應(yīng)選用指針式兆歐表,因?yàn)檫x用數(shù)字顯示的兆歐表,其測(cè)量數(shù)據(jù)有較大的跳動(dòng),從而無法確認(rèn)真實(shí)的阻值,而指針式兆歐表本身對(duì)強(qiáng)磁場(chǎng)干擾比較滯緩(機(jī)械表頭阻尼作用)即使有影響,指針式兆歐表指針表頭顯示也只是有稍微的擺動(dòng),示值范圍也很直觀。)
日本日置HIOKI 3452-11指針式兆歐表--小巧模擬型3量程高電阻計(jì)
每種機(jī)型上有三個(gè)測(cè)量電壓25V、50V、100V,可做絕緣電阻測(cè)試
輕量:只有420g
熒光式刻度盤,在暗處易于操作
活線確認(rèn)功能
電池低電量檢查功能
放電功能(當(dāng)測(cè)試結(jié)束時(shí))
HIOKI 3452-11 兆歐表的基本參數(shù)
3452-11 | 25 V DC (測(cè)試電壓), 10 M-Ω (額定電阻), *有效測(cè)量量程及公差 指示刻度的±5%在0.01 M-Ω ~ 5 M-Ω, 50 V DC ((測(cè)試電壓), 10 M-Ω (額定電阻), *有效測(cè)量量程及公差 指示刻度的±5%在0.01 M-Ω ~ 5 M-Ω, 100 V DC ((測(cè)試電壓), 20 M-Ω (額定電阻), *有效測(cè)量量程及公差 指示刻度的±5%在0.02 M-Ω ~ 10 M-ohm, |
放電功能 | 有效 |
電源供應(yīng) | R6P(AA)×4 |
體積及重量 | 152寬×95高×47厚mm , 420g |
附件 | 9292測(cè)試探頭(1) 9384攜帶盒(1) |
安全等級(jí) | 符合IEC1010,污染度2,設(shè)備類型Ⅲ |
M-ohm HiTESTER 3452-11 to 3452-13
Compact analog three-range insulation resistance meter
Insulation resistance measurement with three testing voltages
Lightweight : only 420 g(14.8 oz)
Luminous scales for ease of use in dark conditions
Live line check function
Low battery check function
Discharge function for removing charge applied by testing
Basic specifications
Model 3452-11 | 25 V DC (testing voltage), 10 M-ohm (rated resistance), First effective measurement range and tolerances ±5 % of scale indication at 0.01 M-ohm to 5 M-ohm, 50 V DC (testing voltage), 10 M-ohm (rated resistance), First effective measurement range and tolerances ±5 % of scale indication at 0.01 M-ohm to 5 M-ohm, 100 V DC (testing voltage), 20 M-ohm (rated resistance), First effective measurement range and tolerances ±5 % of scale indication at 0.02 M-ohm to 10 M-ohm, AC voltage scale 0 to 150 V (50/60 Hz) ±5 % f.s. |
Model 3452-12 | 125 V DC (testing voltage), 20 M-ohm (rated resistance), First effective measurement range and tolerances ±5 % of scale indication at 0.02 M-ohm to 10 M-ohm, 250 V DC (testing voltage), 50 M-ohm (rated resistance), First effective measurement range and tolerances ±5 % of scale indication at 0.05 M-ohm to 20 M-ohm, 500 V DC (testing voltage), 100 M-ohm (rated resistance), First effective measurement range and tolerances ±5 % of scale indication at 0.1 M-ohm to 50 M-ohm, AC voltage scale 0 to 500 V (50/60 Hz) ±5 % f.s. |
Model 3452-13 | 250 V DC (testing voltage), 50 M-ohm (rated resistance), First effective measurement range and tolerances ±5 % of scale indication at 0.05 M-ohm to 20 M-ohm, 500 V DC (testing voltage), 100 M-ohm (rated resistance), First effective measurement range and tolerances ±5 % of scale indication at 0.1 M-ohm to 50 M-ohm, 1000 V DC (testing voltage), 2000 M-ohm (rated resistance), First effective measurement range and tolerances ±5 % of scale indication at 2 M-ohm to 1000 M-ohm, AC voltage scale 0 to 500 V (50/60 Hz) ±5 % f.s. |
Other function | Luminous scales, low battery check function, discharge function |
Power supply | R6P(AA) manganese batteries × 4 |
Dimensions, mass | 152 mm(5.98 in)W × 95 mm(3.74 in)H × 47 mm(1.85 in)D, 420 g (14.8 oz) |
Accessories | TEST PROBE 9292 (1), CARRYING CASE 9384 (1) |