| 注冊| 產(chǎn)品展廳| 收藏該商鋪

行業(yè)產(chǎn)品

當前位置:
深圳市扎克貿易有限公司>> mvi56E-SIEmvi56E-SIE網(wǎng)關 Prosoft

mvi56E-SIE網(wǎng)關 Prosoft

返回列表頁
  • mvi56E-SIE網(wǎng)關 Prosoft
  • mvi56E-SIE網(wǎng)關 Prosoft
收藏
舉報
參考價 面議
具體成交價以合同協(xié)議為準
  • 型號 mvi56E-SIE
  • 品牌 其他品牌
  • 廠商性質 經(jīng)銷商
  • 所在地 深圳市
在線詢價 收藏產(chǎn)品

更新時間:2021-01-26 15:32:51瀏覽次數(shù):355

聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!

同類優(yōu)質產(chǎn)品

更多產(chǎn)品

產(chǎn)品簡介

電動機功率 50kW 外形尺寸 1mm
重量 1kg
mvi56E-SIE網(wǎng)關 Prosoft
BaumerIR08.P02F-F46.PO1Z.7SL瑞士電感傳感器用途:工業(yè)輸送線上用,原理:利用內部電感振蕩器產(chǎn)生一個交變磁場,當金屬產(chǎn)品進入到磁場范圍時,對磁場產(chǎn)生干擾,磁場變化被傳感器感應到并處理轉換為信號,達到檢測有無金屬產(chǎn)品接近目的,功能:檢測有無產(chǎn)品接近,無測量結果顯示0.025975645
RIEGLER226.01-0,2

詳細介紹

mvi56E-SIE網(wǎng)關 Prosoft 

Download the Main AOI and the AOI file that pertains to your meter type. For instance, if the MVI56E-AFC is going to be used for Differential Gas meter runs, you only need the MVI56E-AFC_MeterDifferentialGas_Vx_x.L5X file. You will use these files when you set up your RSLogix project later in this guide. Locating information for your meter type MVI56E-AFC supports the following meters: Meter Type Configured As (Differential or Linear) Turbine Linear Positive Displacement Linear Magnetic Linear Orifice Differential V-Cone Differential. You must configure the meter as V-Cone type in the MVI56E-AFC Manager (Meter Configuration / Calculation Options) Wedge Differential. Refer to Wedge Meter Applications for information about using the wedge meters. Vortex Linear or Differential Ultrasonic Linear or Differential Coriolis Linear or Differential Note: Due to the broad range of meters in the market today, refer to the manufacturer specification to evaluate the use of the module (even if listed here). Note: For Vortex, Ultrasonic, or Coriolis meters, the selection depends on the output generated by the meter. If the meter provides a pulse train representing the volume increment, the MVI56E-AFC should be configured as linear with the primary input set to Pulse Count. If the meter provides instantaneous flow rate, the MVI56-AFC should be configured as differential with the primary input set to Flow Rate.

Warnings North America Warnings Power, Input, and Output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods, Article 501 to 4 (b) of the National Electrical Code, NFPA 70 for installation in the U.S., or as specified in Section 18-1J2 of the Canadian Electrical Code for installations in Canada, and in accordance with the authority having jurisdiction. The following warnings must be heeded: A Warning - Explosion Hazard - Substitution of components may impair suitability for Class I, Division 2. B Warning - Explosion Hazard - When in hazardous locations, turn off power before replacing or rewiring modules. C Warning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous. Avertissement - Risque d'explosion - Avant de déconnecter l'équipement, couper le courant ou s'assurer que l'emplacement est désigné non dangereux. D Suitable for use in Class I, Division 2 Groups A, B, C and D Hazardous Locations or Non-Hazardous Locations. ATEX Warnings and Conditions of Safe Usage Power, Input, and Output (I/O) wiring must be in accordance with the authority having jurisdiction. A Warning - Explosion Hazard - When in hazardous locations, turn off power before replacing or wiring modules. B Warning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous. C These products are intended to be mounted in an IP54 enclosure. The devices shall provide external means to prevent the rated voltage being exceeded by transient disturbances of more than 40%. This device must be used only with ATEX certified backplanes. D DO NOT OPEN WHEN ENERGIZED. Battery Life Advisory The MVI46, MVI56, MVI56E, MVI69, and MVI71 modules use a rechargeable Lithium Vanadium Pentoxide battery to back up the real-time clock and CMOS. The battery should last for the life of the module. The module must be powered for approximately twenty hours before the battery becomes fully charged. After it is fully charged, the battery provides backup power for the CMOS setup and the real-time clock for approximately 21 days. When the battery is fully discharged, the module will revert to the default BIOS and clock settings. Note: The battery is not user replaceable. Electrical Ratings ? Backplane Current Load: 800 mA @ 5.1 Vdc; 3 mA @ 24 Vdc ? Operating Temperature: 0°C to 60°C (32°F to 140°F) ? Storage Temperature: -40°C to 85°C (-40°F to 185°F) ? Shock: 30 g, operational; 50 g, non-operational; Vibration: 5 g from 10 Hz to 150 Hz ? Relative Humidity: 5% to 95% with no condensation ? All phase conductor sizes must be at least 1.3 mm(squared) and all earth ground conductors must be at least 

其他推薦產(chǎn)品

更多產(chǎn)品

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~
二維碼 意見反饋
在線留言