產(chǎn)品簡介
詳細介紹
M2111-01型光子計數(shù)探測器
The M2111-01 photometric detector
本公司研發(fā)的M2111-01型測光探測器主要應用于高能物理、體外診斷、精密測量等領域。M2111-01型測光探測器由側(cè)窗光電倍增管、高壓電源模塊及放大電路組成。本產(chǎn)品具有簡單方便、可靠性高及探測效率高等優(yōu)點,可以采用多方式(電壓調(diào)節(jié)或電阻調(diào)節(jié))控制增益。
The M2111-01 photometric detector developed by our company is mainly used in high energy physics, vitro diagnosis, precision measurement and other fields. M2111-01 photometric detector consists of side window photomultiplier tube, high voltage power supply module and amplifier circuit. The product has the advantages of simple and convenient, high reliability and high detection efficiency, and can be controlled by multiple ways (voltage regulation or resistance regulation) gain.
技術參數(shù)
參數(shù) | Min. | Typ. | Max | 單位 | |
輸入電壓/Input voltage | ±11.5~±12.5 | V | |||
輸入電流/Max input current | 100 | mA | |||
有效面積/Effective area | 8×24 | mm | |||
光譜響應范圍/Spectral range | 165-900 | nm | |||
輻射靈敏度峰值波長/Peak wavelength of radiant sensitivity | 420 | nm | |||
控制電壓/Control voltage | +5 | V | |||
陰極光照靈敏度/Cathode luminous sensitivity | 200 | μA/lm | |||
陰極輻射靈敏度2)Cathode radiant sensitivity | 70 | mA/W | |||
輸出光照靈敏度1)Output luminous sensitivity | 1.2×107 | V/lm | |||
輸出輻射靈敏度1)2)Output ardiant sensitivity | 3.5 | V/nW | |||
紅白比/Red and white ratio | 0.3 | -- | |||
IV變換比/IV conversion ratio | 0.05 | V/μA | |||
線性輸出電壓1)/Maximum linear output voltage | 5 | V | |||
失調(diào)電壓1)3)/Offset voltage | ±2 | mV | |||
紋波噪聲/Ripple noise | 4 | mV | |||
頻率帶寬/ Frequency bandwidth | 500 | kHz | |||
重量/Weight | 225 | g | |||
工作環(huán)境/ work environment | 溫度/Temperature | +5~+40 | ℃ | ||
濕度/Humidity | 90%RH | -- | |||
存放環(huán)境/Storage environment | 溫度/Temperature | -20~+50 | ℃ | ||
濕度Humidity | 93%RH | -- |
1) 控制電壓:+4.0V; 2) 入射光波長:400nm; 3) 預熱時間:30min。
產(chǎn)品應用
生物技術 Biotechnology
醫(yī)療器械 Medical Application
精密測量 Precise measurement
特性曲線
接線及增益調(diào)節(jié)方法
外形尺寸圖
外形尺寸圖(單位mm 線長可定制)