西門子PLC卡件CPU312C
西門子PLC卡件CPU312C
。同號(hào)
, 3117125529
CPU 運(yùn)行需要 SIMATIC 微存儲(chǔ)卡 (MMC)。
CPU 312,zui小的 S7-300 CPU。滿足TIA簡(jiǎn)單應(yīng)用的理想套件,實(shí)現(xiàn)諸如集成的通訊、數(shù)據(jù)管理和診斷等優(yōu)勢(shì)。可使用MPI或CP組網(wǎng),但標(biāo)準(zhǔn)應(yīng)用是單機(jī)-非組網(wǎng)運(yùn)行。I/O通常以一個(gè)集中式組態(tài)結(jié)構(gòu)進(jìn)行連接。
CPU 312 安裝有:
可參數(shù)化的特性
可以使用 STEP 7 對(duì) S7 的組態(tài)、屬性以及CPU的響應(yīng)進(jìn)行參數(shù)設(shè)置:
顯示功能與信息功能
集成的通訊功能
系統(tǒng)功能
CPU 具有廣泛的系統(tǒng)功能特性,諸如:診斷、參數(shù)賦值、報(bào)警、定時(shí)和測(cè)量等。
詳細(xì)信息請(qǐng)參見(jiàn)手冊(cè)。
Article number | 6ES7312-1AE14-0AB0 | |
---|---|---|
| CPU312, 32KB | |
General information |
| |
HW functional status | 01 | |
Firmware version | V3.3 | |
Engineering with |
| |
| STEP 7 V5.5 + SP1 or higher or STEP 7 V5.2 + SP1 or higher with HSP 218 | |
Supply voltage |
| |
Rated value (DC) |
| |
| Yes | |
permissible range, lower limit (DC) | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | |
external protection for power supply lines (recommendation) | 2 A min. | |
Mains buffering |
| |
| 5 ms | |
| 1 s | |
Input current |
| |
Current consumption (rated value) | 650 mA | |
Current consumption (in no-load operation), typ. | 140 mA | |
Inrush current, typ. | 3.5 A | |
I²t | 1 A²·s | |
Power loss |
| |
Power loss, typ. | 4 W | |
Memory |
| |
Work memory |
| |
| 32 kbyte | |
| No | |
| 32 kbyte | |
Load memory |
| |
| Yes | |
| 8 Mbyte | |
| 10 y | |
Backup |
| |
| Yes; Guaranteed by MMC (maintenance-free) | |
| Yes; Program and data | |
CPU processing times |
| |
for bit operations, typ. | 0.1 µs | |
for word operations, typ. | 0.24 µs | |
for fixed point arithmetic, typ. | 0.32 µs | |
for floating point arithmetic, typ. | 1.1 µs | |
CPU-blocks |
| |
Number of blocks (total) | 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. | |
DB |
| |
| 1 024; Number range: 1 to 16000 | |
| 32 kbyte | |
FB |
| |
| 1 024; Number range: 0 to 7999 | |
| 32 kbyte | |
FC |
| |
| 1 024; Number range: 0 to 7999 | |
| 32 kbyte | |
OB |
| |
| see instruction list | |
| 32 kbyte | |
| 1; OB 1 | |
| 1; OB 10 | |
| 2; OB 20, 21 | |
| 4; OB 32, 33, 34, 35 | |
| 1; OB 40 | |
| 1; OB 100 | |
| 4; OB 80, 82, 85, 87 | |
| 2; OB 121, 122 | |
Nesting depth |
| |
| 16 | |
| 4 | |
Counters, timers and their retentivity |
| |
S7 counter |
| |
| 256 | |
Retentivity |
| |
| Yes | |
| 0 | |
| 255 | |
| Z 0 to Z 7 | |
Counting range |
| |
| 0 | |
| 999 | |
IEC counter |
| |
| Unlimited (limited only by RAM capacity) | |
S7 times |
| |
| 256 | |
Retentivity |
| |
| Yes | |
| 0 | |
| 255 | |
| No retentivity | |
Time range |
| |
| 10 ms | |
| 9 990 s | |
IEC timer |
| |
| Yes | |
| SFB | |
| Unlimited (limited only by RAM capacity) | |
Data areas and their retentivity |
| |
retentive data area in total | All (incl. memory bits, times, counters) | |
Flag |
| |
| 256 byte | |
| Yes; MB 0 to MB 255 | |
| MB 0 to MB 15 | |
| 8; 1 memory byte | |
Data blocks |
| |
| 1 024; Number range: 1 to 16000 | |
| 32 kbyte | |
| Yes; via non-retain property on DB | |
| Yes | |
Local data |
| |
| 32 kbyte; Max. 2 KB per block | |
Address area |
| |
I/O address area |
| |
| 1 024 byte | |
| 1 024 byte | |
Process image |
| |
| 1 024 byte | |
| 1 024 byte | |
| 1 024 byte | |
| 1 024 byte | |
| 128 byte | |
| 128 byte | |
Digital channels |
| |
| 256 | |
| 256 | |
| 256 | |
| 256 | |
Analog channels |
| |
| 64 | |
| 64 | |
| 64 | |
| 64 | |
Hardware configuration |
| |
Number of expansion units, max. | 0 | |
Number of DP masters |
| |
| 0 | |
| 4 | |
Number of operable FMs and CPs (recommended) |
| |
| 8 | |
| 8 | |
| 4 | |
Rack |
| |
| 1 | |
| 8 | |
Time of day |
| |
Clock |
| |
| Yes | |
| No; Buffered: No, Can be synchronized: Yes | |
| 10 s; Typ.: 2 s | |
| The clock continues at the time of day it had when power was switched off | |
Operating hours counter |
| |
| 1 | |
| 0 | |
| 0 to 2^31 hours (when using SFC 101) | |
| 1 hour | |
| Yes; Must be restarted at each restart | |
Clock synchronization |
| |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| No | |
Digital inputs |
| |
Number of digital inputs | 0 | |
Digital outputs |
| |
Number of digital outputs | 0 | |
Analog inputs |
| |
Number of analog inputs | 0 | |
Analog outputs |
| |
Number of analog outputs | 0 | |
Interfaces |
| |
Number of industrial Ethernet interfaces | 0 | |
Number of RS 485 interfaces | 1; MPI | |
Number of RS 422 interfaces | 0 | |
1. Interface |
| |
Interface type | Integrated RS 485 interface | |
Physics | RS 485 | |
Isolated | No | |
Power supply to interface (15 to 30 V DC), max. | 200 mA | |
Functionality |
| |
| Yes | |
| No | |
| No | |
| No | |
MPI |
| |
| 187.5 kbit/s | |
Services |
| |
| Yes | |
| No | |
| Yes | |
| Yes | |
| Yes; Only server, configured on one side | |
| No | |
| Yes | |
Communication functions |
| |
PG/OP communication | Yes | |
Data record routing | No | |
Global data communication |
| |
| Yes | |
| 8 | |
| 8 | |
| 8 | |
| 8 | |
| 22 byte | |
| 22 byte | |
S7 basic communication |
| |
| Yes | |
| 76 byte | |
| 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) | |
S7 communication |
| |
| Yes | |
| Yes | |
| Yes; Via CP and loadable FB | |
| 180 byte; With PUT/GET | |
| 240 byte; as server | |
S5 compatible communication |
| |
| Yes; via CP and loadable FC | |
Number of connections |
| |
| 6 | |
| 5 | |
| 1 | |
| 1 | |
| 5 | |
| 5 | |
| 1 | |
| 1 | |
| 5 | |
| 2 | |
| 0 | |
| 0 | |
| 2 | |
S7 message functions |
| |
Number of login stations for message functions, max. | 6; Depending on the configured connections for PG/OP and S7 basic communication | |
Process diagnostic messages | Yes | |
simultaneously active Alarm-S blocks, max. | 300 | |
Test commissioning functions |
| |
Status block | Yes; Up to 2 simultaneously | |
Single step | Yes | |
Number of breakpoints | 4 | |
Status/control |
| |
| Yes | |
| Inputs, outputs, memory bits, DB, times, counters | |
| 30 | |
| 30 | |
| 14 | |
Forcing |
| |
| Yes | |
| Inputs, outputs | |
| 10 | |
Diagnostic buffer |
| |
| Yes | |
| 500 | |
| No | |
| 100; Only the last 100 entries are retained | |
| 499 | |
| Yes; From 10 to 499 | |
| 10 | |
Service data |
| |
| Yes | |
Ambient conditions |
| |
Ambient temperature during operation |
| |
| 0 °C | |
| 60 °C | |
Configuration |
| |
Configuration software |
| |
| Yes; V5.2 SP1 or higher with HW update | |
Programming |
| |
| see instruction list | |
| 8 | |
| see instruction list | |
| see instruction list | |
Programming language |
| |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
Know-how protection |
| |
| Yes | |
| Yes; With S7 block Privacy | |
Dimensions |
| |
Width | 40 mm | |
Height | 125 mm | |
Depth | 130 mm | |
Weights |
| |
Weight, approx. | 270 g |