CNX-1 膠帶持粘性測(cè)試儀五工位三工位 適用于自粘卷材、壓敏膠粘帶、醫(yī)用貼劑、不干膠標(biāo)簽、保護(hù)膜、膏藥、巴布膏等產(chǎn)品進(jìn)行持粘性測(cè)試。
![714.jpg](https://img79.chem17.com/75f0e85efce44cd2746275c05897099d26c9d28f6bde01c71b47ac6f5da50728021577bde02b775c.jpg)
![715.jpg](https://img79.chem17.com/75f0e85efce44cd2746275c05897099dab08c1d36513cb548046d44639fe974421265d5c1400f50a.jpg)
![637811385380201736127.jpg](https://img75.chem17.com/75f0e85efce44cd27e1da01378ccdc287d331db0fa33d589489d7e94b7e6e576ff773bd19590c558.jpg)
CNX-1 膠帶持粘性測(cè)試儀五工位三工位 主要適用于自粘卷材、壓敏膠粘帶、醫(yī)用貼劑、不干膠標(biāo)簽、保護(hù)膜、膏藥、巴布膏等產(chǎn)品進(jìn)行持粘性測(cè)試試驗(yàn)。
執(zhí)行標(biāo)準(zhǔn):GB4851壓敏膠粘帶持粘性試驗(yàn)方法
ASTM D3654壓敏膠織帶剪切粘性的標(biāo)準(zhǔn)試驗(yàn)方法
JIS Z0237亞敏粘膠帶及亞敏粘膠薄板的試驗(yàn)方法
持粘性定義:
沿粘貼在被粘物上的壓敏膠帶長(zhǎng)度方向垂直懸掛一規(guī)定重量的砝碼時(shí),膠粘帶抵抗位移的能力。
用試片移動(dòng)一定距離的時(shí)間或一定時(shí)間內(nèi)移動(dòng)距離表示。
![637811385370166405578.jpg](https://img71.chem17.com/75f0e85efce44cd27e1da01378ccdc28367168879c6d224bea6a961b2fd62b4bc3fd33ad56cd8268.jpg)
CNX-1 膠帶持粘性測(cè)試儀五工位三工位
技術(shù)參數(shù):
標(biāo)準(zhǔn)壓輥:2000g±5g
砝碼:1000g±10g(含加載板重量)
實(shí)驗(yàn)板:70mm(L)x60mm(W)x1.5mm(D)
計(jì)時(shí)范圍:0~100h(標(biāo)準(zhǔn)配置)
0~10000h(可選)
工位數(shù):5件
外形尺寸:360mm(L)x240mm(W)x420mm(H)
電源:AC220V 50HZ
凈重:20kg
![637811385378354954879.jpg](https://img73.chem17.com/75f0e85efce44cd27e1da01378ccdc28683012f12b2b71795816ae9cd3df0480a920a49498c8094a.jpg)
1、嚴(yán)格按照標(biāo)準(zhǔn)設(shè)計(jì)的試驗(yàn)板和測(cè)試砝碼,確保了檢測(cè)數(shù)據(jù)的準(zhǔn)確性。
2、系統(tǒng)有按鍵開(kāi)關(guān)和LED液晶顯示屏,方便用戶(hù)快速地進(jìn)行實(shí)驗(yàn)操作和數(shù)據(jù)查看。
3、五個(gè)測(cè)試工位可同時(shí)進(jìn)行多組測(cè)試項(xiàng)目。
4、計(jì)時(shí)、鎖定等功能進(jìn)一步確保實(shí)驗(yàn)結(jié)果的高精準(zhǔn)性。
測(cè)試原理:
把貼有膠粘試樣的試驗(yàn)板垂直吊掛在試驗(yàn)架上,下端懸掛規(guī)定重量的砝碼,用一定時(shí)間后試驗(yàn)粘脫的位移量或試驗(yàn)*脫離的時(shí)間來(lái)表示膠粘試樣抵抗拉脫的能力。
![](https://img73.chem17.com/75f0e85efce44cd27e1da01378ccdc28357adc3a2fdf25ed75b028f5c64551fafe27c37502759db8.jpg)
![細(xì)節(jié)1.jpg](https://img79.chem17.com/75f0e85efce44cd2746275c05897099ddd7ac940ad5eb69a9280439f01e1b68ace5a27d7c62f7a77.jpg)
![細(xì)節(jié)2.jpg](https://img79.chem17.com/75f0e85efce44cd2746275c05897099d0e3a86137d51bfc98252b4a988c80a8e4621f40298f68f04.jpg)
![細(xì)節(jié)3.jpg](https://img79.chem17.com/75f0e85efce44cd2746275c05897099d3b3b20e5a532a1534de7324a57007ae021012fbff1b9a92e.jpg)
![細(xì)節(jié)4.jpg](https://img76.chem17.com/75f0e85efce44cd2746275c05897099df5cd010fea808ca4cc23161c963b5ffe7cf0088c2f058518.jpg)
![細(xì)節(jié)5.jpg](https://img80.chem17.com/75f0e85efce44cd2746275c05897099d672bf5db0e98a9b2c0ca7d072c2ea5490943c1fae109bd7c.jpg)
![細(xì)節(jié)6.jpg](https://img76.chem17.com/75f0e85efce44cd2746275c05897099d09a14dd428384a3611e07c4eadeb5dd00c37e559c2a6eed0.jpg)
![](https://img71.chem17.com/75f0e85efce44cd27e1da01378ccdc287e166bce6295a23a19c8e2d88231330a98b19159f3687dee.jpg)
![71.jpg](https://img77.chem17.com/75f0e85efce44cd2746275c05897099dfd2390eeebc9c7c0c4f3ff0efe6f5878bdff76d9c6947d8b.jpg)
![77.jpg](https://img79.chem17.com/75f0e85efce44cd2746275c05897099d758376ad6d9a0b40f21967631fb8084bf237e6a60bbd08cf.jpg)
![711.jpg](https://img79.chem17.com/75f0e85efce44cd2746275c05897099d708a35fec208444406b09146581aea37ac4231d5ffa1398b.jpg)
![777.jpg](https://img79.chem17.com/75f0e85efce44cd2746275c05897099d39ad83de668f5e5ecf10642f45e448cf0ec1f3fa8493ed86.jpg)
![77777.jpg](https://img77.chem17.com/75f0e85efce44cd2746275c05897099d404874216130d72ff2aa7c89876f32c2a330360d34fd2432.jpg)
![3.jpg](https://img77.chem17.com/75f0e85efce44cd2746275c05897099d4d07c7127322f9f135d7195e2f16071e16aa799801001009.jpg)
![33.jpg](https://img77.chem17.com/75f0e85efce44cd2746275c05897099d926026b441f32b0332632cb587c6a72579618bbe1c0b9de0.jpg)
![637811385373442405591.jpg](https://img71.chem17.com/75f0e85efce44cd27e1da01378ccdc28934643588fdc21c751592b4f59bff3df45c30c6a748e723a.jpg)
1、水平放置儀器,打開(kāi)電源開(kāi)關(guān),并將砝碼放置在吊架下方槽內(nèi)。
2、除去膠粘帶試卷最外層的3~5圈膠粘帶后,以約300mm/min的速率解開(kāi)試樣卷(對(duì)片狀試樣也以同樣速率揭去其隔離層),每隔200mm左右,在膠粘帶中部裁取寬25mm、長(zhǎng)約100mm的試樣。除非另有規(guī)定,每組試樣的數(shù)量不少于三個(gè)。
3、用擦拭材料蘸清洗劑擦洗試驗(yàn)板和加載板,然后用干凈的紗布將其仔細(xì)擦干,如此反復(fù)清洗三次以上,直至板的工作面經(jīng)目視檢查達(dá)到清潔為止。清洗以后,不得用手或其他物料接觸板的工作面。
4、在溫度23℃±2℃、相對(duì)濕度62%±5%的條件下,按規(guī)定的尺寸將試樣平行于板的縱向粘貼在緊挨著的試驗(yàn)板和加載板的中部。用壓輥以約300mm/min的速度在試樣上滾壓。注意滾壓時(shí)只能用產(chǎn)生于壓輥質(zhì)量的力施加于試樣上。滾壓的次數(shù)可根據(jù)具體產(chǎn)品情況加以規(guī)定,如無(wú)規(guī)定,則往復(fù)滾壓三次。
5、試樣在板上粘貼后,應(yīng)在溫度23℃±2℃、相對(duì)濕度62%±5%的條件下放置20min,然后將試驗(yàn)板垂直固定在試驗(yàn)架上,輕輕把砝碼連接到加載板上。整個(gè)試驗(yàn)架置于已調(diào)整到所要求的的試驗(yàn)環(huán)境下或試驗(yàn)箱內(nèi)。
6、按開(kāi)始鍵開(kāi)始計(jì)時(shí)。
7、到達(dá)規(guī)定時(shí)間后,卸去重物。用帶分度的放大鏡測(cè)出試樣下滑的位移量,精確至0.1mm;或者記錄試樣從試驗(yàn)板上脫落的時(shí)間(常用方法)。時(shí)間數(shù)≥1h的,以min為單位,<1h的以s為單位。